CYRF6936
Document #: 38-16015 Rev. *F Page 32 of 39
Figure 13-1. SPI Timing
Parameter Description Conditions Min. Typ. Max. Unit
I
LOAD_EXT
Average PMU External Load current V
BAT
= 1.8V, V
REG
= 2.73V,
0–50°C, RX Mode
15 mA
I
LOAD_EXT
Average PMU External Load current V
BAT
= 1.8V, V
REG
= 2.73V,
50–70°C, RX Mode
10 mA
13.0 AC Characteristics
[12]
Table 13-1. SPI Interface
[13]
Parameter Description Min. Typ. Max. Unit
t
SCK_CYC
SPI Clock Period 238.1 ns
t
SCK_HI
SPI Clock High Time 100 ns
t
SCK_LO
SPI Clock Low Time 100 ns
t
DAT_SU
SPI Input Data Set-up Time 25 ns
t
DAT_HLD
SPI Input Data Hold Time 10 ns
t
DAT_VAL
SPI Output Data Valid Time 0 50 ns
t
DAT_VAL_TRI
SPI Output Data Tri-state (MOSI from Slave Select Deassert) 20 ns
t
SS_SU
SPI Slave Select Set-up Time before first positive edge of SCK
[14]
10 ns
t
SS_HLD
SPI Slave Select Hold Time after last negative edge of SCK 10 ns
t
SS_PW
SPI Slave Select Minimum Pulse Width 20 ns
t
SCK_SU
SPI Slave Select Set-up Time 10 ns
t
SCK_HLD
SPI SCK Hold Time 10 ns
t
RESET
Minimum RST pin pulse width 10 ns
12.0 DC Characteristics(T = 25°C, V
BAT
= 2.4V, PMU disabled, f
OSC
= 12.000000MHz) (continued)
SCK
nSS
MOSI input
MISO
MOSI output
t
SCK_HI
t
SCK_LO
t
SS_SU
t
SCK_SU
t
SCK_CYC
t
SS_HLD
t
SCK_HLD
t
DAT_SU
t
DAT_HLD
t
DAT_VAL
t
DAT_VAL_TRI
Notes
12. AC values are not guaranteed if voltage on any pin exceed V
IO
.
13. C
LOAD
= 30 pF.
14. SCK must start low at the time SS
goes low, otherwise the success of SPI transactions are not guaranteed.